2. For the Master and Slave, ensure the Azimuth (AZ) and
Elevation (EL) Adjustment Bolts are in the middle of their
adjustmentranges.
Elevation (EL)
Adjustment Bolt
Azimuth (AZ)
Adjustment Bolt
3. Master Aim the Master at the Slave. If necessary, adjust the
Master's position on the pole:
a. Loosen the Hex Nuts.
b. Adjust the Pole Mount Bracket and Pole Clamps.
c. Tighten the Hex Nuts.
Hex Nuts
4. Slave Aim the Slave at the Master to achieve the strongest
received signal level on the Slave's numeric LED Display, which
is located next to the CONFIG port. If necessary, adjust the
Slave's position on the pole.
Slave RF Power (-dBm)
Note: Values on the LED Display are displayed in
negative (-) dBm. For example, 61 represents -61dBm,
which is stronger than -72 dBm.